# Synthetic CT generation from MRI using 3D transformer‐based denoising diffusion model

Article · Shaoyan Pan, Elham Abouei, Jacob Frank Wynne, Chih‐Wei Chang, Tonghe Wang, Richard L. J. Qiu, Yuheng Li, Junbo Peng, Justin R. Roper, Pretesh R Patel, David S. Yu, Hui Z. Mao, Xiaofeng Yang

- Archive id: arxiv:2305.19467
- Published: 2023-11-27
- Venue: Medical Physics
- DOI: https://doi.org/10.1002/mp.16847
- arXiv: https://arxiv.org/abs/2305.19467
- PMID: 38011588
- Citations: 144
- Source URL: https://doi.org/10.1002/mp.16847
- PDF: https://pmc.ncbi.nlm.nih.gov/articles/PMC10994752/pdf/nihms-1947131.pdf
- Provenance: openalex+arxiv

## Abstract

Magnetic resonance imaging (MRI)-based synthetic computed tomography (sCT) simplifies radiation therapy treatment planning by eliminating the need for CT simulation and error-prone image registration, ultimately reducing patient radiation dose and setup uncertainty. We propose an MRI-to-CT transformer-based denoising diffusion probabilistic model (MC-DDPM) to transform MRI into high-quality sCT to facilitate radiation treatment planning. MC-DDPM implements diffusion processes with a shifted-window transformer network to generate sCT from MRI. The proposed model consists of two processes: a forward process which adds Gaussian noise to real CT scans, and a reverse process in which a shifted-window transformer V-net (Swin-Vnet) denoises the noisy CT scans conditioned on the MRI from the same patient to produce noise-free CT scans. With an optimally trained Swin-Vnet, the reverse diffusion process was used to generate sCT scans matching MRI anatomy. We evaluated the proposed method by generating sCT from MRI on a brain dataset and a prostate dataset. Qualitative evaluation was performed using the mean absolute error (MAE) of Hounsfield unit (HU), peak signal to noise ratio (PSNR), multi-scale Structure Similarity index (MS-SSIM) and normalized cross correlation (NCC) indexes between ground truth CTs and sCTs. MC-DDPM generated brain sCTs with state-of-the-art quantitative results with MAE 43.317 HU, PSNR 27.046 dB, SSIM 0.965, and NCC 0.983. For the prostate dataset, MC-DDPM achieved MAE 59.953 HU, PSNR 26.920 dB, SSIM 0.849, and NCC 0.948. In conclusion, we have developed and validated a novel approach for generating CT images from routine MRIs using a transformer-based DDPM. This model effectively captures the complex relationship between CT and MRI images, allowing for robust and high-quality synthetic CT (sCT) images to be generated in minutes.

_Abstract reproduced under CC0-1.0 (arXiv descriptive metadata)._

Topics: [Generative & Multimodal Models](https://space-kitty.com/topics/generative-multimodal)

---
Space Kitty Archive · https://space-kitty.com · API: https://space-kitty.com/api/v1 · MCP: https://space-kitty.com/mcp · Premium: $0.20/request via x402 (Base Sepolia (testnet)). Metadata: arXiv (CC0), OpenAlex (CC0), Europe PMC (CC BY/CC0 works), ClinicalTrials.gov.
