# Full‐dose whole‐body PET synthesis from low‐dose PET using high‐efficiency denoising diffusion probabilistic model: PET consistency model

Article · Shaoyan Pan, Elham Abouei, Junbo Peng, Joshua Y. Qian, Jacob Frank Wynne, Tonghe Wang, Chih‐Wei Chang, Justin R. Roper, Jonathon A. Nye, Hui Z. Mao, Xiaofeng Yang

- Archive id: arxiv:2308.13072
- Published: 2024-04-08
- Venue: Medical Physics
- DOI: https://doi.org/10.1002/mp.17068
- arXiv: https://arxiv.org/abs/2308.13072
- PMID: 38588512
- Citations: 39
- Source URL: https://doi.org/10.1002/mp.17068
- PDF: https://pmc.ncbi.nlm.nih.gov/articles/PMC11321936/pdf/nihms-1983383.pdf
- Provenance: openalex+arxiv

## Abstract

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients. Approach: We introduce PET Consistency Model (PET-CM), an efficient diffusion-based method for generating high-quality full-dose PET images from low-dose PET images. It employs a two-step process, adding Gaussian noise to full-dose PET images in the forward diffusion, and then denoising them using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion. The PET-VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full-dose PET images. PET-CM achieves state-of-the-art image quality while requiring significantly less computation time than other methods. Results: In experiments comparing eighth-dose to full-dose images, PET-CM demonstrated impressive performance with NMAE of 1.278+/-0.122%, PSNR of 33.783+/-0.824dB, SSIM of 0.964+/-0.009, NCC of 0.968+/-0.011, HRS of 4.543, and SUV Error of 0.255+/-0.318%, with an average generation time of 62 seconds per patient. This is a significant improvement compared to the state-of-the-art diffusion-based model with PET-CM reaching this result 12x faster. Similarly, in the quarter-dose to full-dose image experiments, PET-CM delivered competitive outcomes, achieving an NMAE of 0.973+/-0.066%, PSNR of 36.172+/-0.801dB, SSIM of 0.984+/-0.004, NCC of 0.990+/-0.005, HRS of 4.428, and SUV Error of 0.151+/-0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario.

_Abstract reproduced under CC0-1.0 (arXiv descriptive metadata)._

Topics: [Generative & Multimodal Models](https://space-kitty.com/topics/generative-multimodal)

---
Space Kitty Archive · https://space-kitty.com · API: https://space-kitty.com/api/v1 · MCP: https://space-kitty.com/mcp · Premium: $0.20/request via x402 (Base Sepolia (testnet)). Metadata: arXiv (CC0), OpenAlex (CC0), Europe PMC (CC BY/CC0 works), ClinicalTrials.gov.