# Quench Performance of the First Pre-series AUP Cryo-assembly

Preprint · M. Baldini, G. Chlachidze, G. Apollinari, J. Dimarco, S. Feher, V. Nikolic, D. Orris, R. Rabehl, S. Stoynev, T. Strauss, M. Tartaglia, A. Vouris

- Archive id: arxiv:2403.00171
- Published: 2024-02-29
- DOI: https://doi.org/10.1109/tasc.2024.3358777
- arXiv: https://arxiv.org/abs/2403.00171
- Source URL: https://arxiv.org/abs/2403.00171
- PDF: https://arxiv.org/pdf/2403.00171
- Provenance: arxiv

## Abstract

The High Luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN will include eight cryo-assemblies that are expected to be fabricated and delivered to CERN by the US HL-LHC Accelerator Upgrade Project (AUP) as part of the U.S. contributions to the HL-LHC. These cryostat assemblies are the quadrupole magnetic components of the HL-LHC Q1 and Q3 inner triplet optical elements in front of the two interaction points. Each cryo-assembly consists of two 4.2 m long Nb3Sn quadrupole magnets with aperture 150 mm and operating gradient 132.6 T/m. The first pre-series cryo-assembly has been fabricated and successfully tested at the horizontal test facility at Fermi National Accelerator Laboratory. In this manuscript we report the quench test results of the LQXFA/B-01 cryo-assembly. The primary objective of the horizontal test is full cryo-assembly qualification and validation of the performance requirements.

_Abstract reproduced under CC0-1.0 (arXiv descriptive metadata)._

---
Space Kitty Archive · https://space-kitty.com · API: https://space-kitty.com/api/v1 · MCP: https://space-kitty.com/mcp · Premium: $0.20/request via x402 (Base Sepolia (testnet)). Metadata: arXiv (CC0), OpenAlex (CC0), Europe PMC (CC BY/CC0 works), ClinicalTrials.gov.