# Matched-Input Estimates Differ in Sign Across Architectures: Auditing EEG Foundation Models on Motor Imagery

Preprint · Kevin Zhou, Sparsh Roy

- Archive id: arxiv:2609.23924
- Published: 2026-09-20
- arXiv: https://arxiv.org/abs/2609.23924
- Citations: 0
- Source URL: https://arxiv.org/abs/2609.23924
- PDF: https://arxiv.org/pdf/2609.23924
- Provenance: arxiv

## Abstract

Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree about when their representations transfer to downstream tasks. We audit LaBraM and CBraMod on motor imagery under a validation-locked protocol in which preprocessing, architecture, optimization, freeze depth, checkpoint, temperature, and method selection are determined using training-session data only. On four-class BCI Competition IV-2a, every supervised comparator evaluated here outperforms every foundation-model configuration, including validation-selected fine-tuning. We then examine a key confound: foundation models and task-specific decoders are normally evaluated using different input pipelines. Retraining three supervised architectures on the broadband arrays consumed by the foundation models produces matched-input accuracy differences of opposite sign across architectures: broadband input improves ATCNet by 0.078 accuracy while reducing EEG Conformer accuracy by 0.088. None of the three individual matched-input terms is significant after multiple-comparison correction at n = 9, so we treat the sign variation descriptively rather than as a formal architecture-by-pipeline interaction. These observed sign differences suggest that a single comparator may not provide an architecture-invariant decomposition of a pretrained-versus-supervised performance gap. The four-class deficit also does not reproduce uniformly across motor-imagery datasets: on two-class BNCI2014-004 we cannot detect the same separation between fine-tuned CBraMod and the supervised comparators. Finally, validation-fitted temperature scaling returns foundation-model calibration error to the supervised range despite substantially lower four-class accuracy.

_Abstract reproduced under CC0-1.0 (arXiv descriptive metadata)._

Topics: [Brain-Computer Interfaces](https://space-kitty.com/topics/brain-computer-interfaces)

---
Space Kitty Archive · https://space-kitty.com · API: https://space-kitty.com/api/v1 · MCP: https://space-kitty.com/mcp · Premium: $0.20/request via x402 (Base Sepolia (testnet)). Metadata: arXiv (CC0), OpenAlex (CC0), Europe PMC (CC BY/CC0 works), ClinicalTrials.gov.
