# OpenMAP-HIE: Pathology Informed Score-based Diffusion Model for Unsupervised Neonatal Hypoxic-Ischemic Encephalopathy Lesion Segmentation

Preprint · Pengyu Kan, Craig Jones, Kenichi Oishi

- Archive id: arxiv:2610.29322
- Published: 2026-10-21
- arXiv: https://arxiv.org/abs/2610.29322
- Source URL: https://arxiv.org/abs/2610.29322
- PDF: https://arxiv.org/pdf/2610.29322
- Provenance: arxiv

## Abstract

Accurate localization of neonatal hypoxic--ischemic encephalopathy (HIE) lesions on apparent diffusion coefficient (ADC) images is clinically important but is limited by scarce expert annotations and substantial variation in lesion appearance. We propose OpenMAP-HIE, a pathology-informed score-based diffusion model for unsupervised HIE lesion localization without voxel-wise lesion supervision. A denoising diffusion model learns the healthy neonatal ADC distribution, while a ControlNet-based conditional branch preserves patient-specific anatomy. At inference, anomaly evidence is derived directly from differences between conditional and unconditioned noise predictions at independently evaluated diffusion noise levels, avoiding dependence on a final pseudo-healthy reconstruction or sequential reverse-diffusion chain. Based on the characteristic ADC reduction associated with acute HIE, only discrepancies consistent with the expected pathological direction are retained and aggregated across noise levels using a geometric mean. Spatial mean filtering further suppresses isolated responses. The framework was evaluated on the BONBID-HIE dataset. The ADC-only method achieved a Dice score of $0.283\\pm0.244$, average precision of $0.505$, Hausdorff distance of $25.45\\pm15.63$ mm, mean average surface distance of $9.40\\pm8.49$ mm, and normalized surface distance of $0.355\\pm0.236$, providing the best overlap and surface-distance performance among the evaluated unsupervised methods and Dice performance comparable to supervised ADC-only models. Optional population-derived ADC $Z$-map refinement further increased Dice to $0.602\\pm0.269$. These findings support pathology-informed score discrepancies as a useful signal for neonatal HIE lesion localization, while highlighting remaining challenges in detecting small and low-contrast lesions.

_Abstract reproduced under CC0-1.0 (arXiv descriptive metadata)._

---
Space Kitty Archive · https://space-kitty.com · API: https://space-kitty.com/api/v1 · MCP: https://space-kitty.com/mcp · Premium: $0.20/request via x402 (Base Sepolia (testnet)). Metadata: arXiv (CC0), OpenAlex (CC0), Europe PMC (CC BY/CC0 works), ClinicalTrials.gov.
