# Towards green monitoring of antibiotics: a direct biochar-based electrochemical sensor for ampicillin detection in biomedical and environmental matrices

Article · Macovei DG, Tertis M, Balla A, Kacsó I, Leoştean C, Tripon S, Suciu M, Cherecheş RM, Cristea C, Oprean R

- Archive id: doi:10.1016/j.talanta.2026.130619
- Published: 2026-09-15
- Venue: Talanta
- DOI: https://doi.org/10.1016/j.talanta.2026.130619
- PMID: 42762756
- Citations: 0
- Source URL: https://doi.org/10.1016/j.talanta.2026.130619
- Provenance: europepmc

## Abstract

Antimicrobial resistance (AMR) represents a global health burden, requiring effective monitoring of antibiotic residues across the clinical-environmental chain. However, reference methods remain laboratory-based and solvent-intensive. To address this need in an ecologically responsible manner, this study exploits KOH-activated biochar derived from spent coffee grounds (BCK-KOH) as a screen-printed carbon electrode modifier for the direct detection of ampicillin (AMP); the corresponding non-activated material is denoted BCK. Characterization by N 2 adsorption, FTIR, XPS and SEM-EDS revealed a 168-fold increase in BET surface area and substantial enrichment in surface carboxyl groups following activation. Modification with a PEI/BCK-KOH composite produced a ∼370 mV cathodic shift of the AMP oxidation signal compared with the unmodified electrode. Under optimized differential pulse voltammetry (DPV), the platform exhibited a linear range of 0.01-5 μM, an LOD of 3.3 nM, an LOQ of 10 nM and a sensitivity of 64.7 μA μM -1 (R 2 = 0.997). The sensor showed acceptable interference tolerance toward the tested antibiotics and common endogenous compounds. Validation in artificial and ICU-patient serum, milk and water samples yielded recoveries of 88.5-111.4% with RSDs below 5.6% (n = 3), without pre-treatment. Because the LOQ closely matches the EU maximum residue limit (MRL) for AMP in milk, the platform enabled quantitative determination at approximately the MRL, 1.5×MRL and 2×MRL, with recoveries of 90.9%, 101.9% and 100.9%, respectively, while also supporting qualitative MRL screening in diluted samples complementary to confirmatory LC-MS/MS. AGREE (0.75) and BAGI (67.5) scores confirmed a substantially greener analytical platform than LC-MS/MS (AGREE 0.43) with practical applicability.

_Abstract reproduced under CC-BY (article license as recorded by Europe PMC; abstract reproduced unmodified apart from markup removal)._

Topics: [Infectious Disease, Vaccines & Antimicrobial Resistance](https://space-kitty.com/topics/infectious-disease-amr)

---
Space Kitty Archive · https://space-kitty.com · API: https://space-kitty.com/api/v1 · MCP: https://space-kitty.com/mcp · Premium: $0.20/request via x402 (Base Sepolia (testnet)). Metadata: arXiv (CC0), OpenAlex (CC0), Europe PMC (CC BY/CC0 works), ClinicalTrials.gov.