A longitudinal study of field emission in CEBAF's SRF cavities 1995-2015

Jay Benesch

View at source ↗PDF ↗Preprint1 citations
Preprint: not peer reviewed. Results may change in later versions.

Abstract

Field emission is one of the key issues in superconducting RF. When present, it limits operating gradient directly or via induced heat load at 2K. In order to minimize particulate contamination of and thus field emission in the CEBAF SRF cavities during assembly, a ceramic RF window was placed very close to the accelerating cavity proper. As an unintended consequence of this, it has been possible to monitor and model field emission in the CEBAF cavities since in-tunnel operation began. The ceramic is charged by field emission to a stable voltage and then discharges. This phenomenon had to be studied statistically to minimize the number of interruptions to accelerator operation for nuclear physics. We report here the results of our twenty year study of this and related phenomena.

Abstract: arXiv descriptive metadata (CC0). Thank you to arXiv for use of its open access interoperability. This service was not reviewed or approved by, nor does it necessarily express or reflect the policies or opinions of, arXiv.

Record

Archive ID
arxiv:1502.06877
Published
Feb 24, 2015
Updated
Oct 11, 2015
arXiv
1502.06877
Categories
physics.acc-ph, cond-mat.supr-con, hep-ex, nucl-ex
Provenance
arxiv

Topics