Advances in secondary ion mass spectroscopy

Jonathan Angle, Ari Palczewski, Charles E. Reece, Fred A. Stevies, Michael J. Kelley

Preprint: not peer reviewed. Results may change in later versions.

Abstract

Accurate SIMS measurement of nitrogen in niobium relies on the use of closely equivalent standards, made by ion implantation, to convert nitrogen signal intensity to nitrogen content by determination of relative sensitivity factors (RSF). Accurate RSF values for ppm-range nitrogen contents are increasingly critical, as more precision is sought in processes for next-generation superconducting radio-frequency (SRF) accelerator cavities. Factors influencing RSF value measurements were investigated with the aim of reliably attaining better than 10% accuracy in N concentrations at various depths into the bulk. This has been accomplished for materials typical of SRF cavities at the cost of great attention to all aspects.

Abstract: arXiv descriptive metadata (CC0). Thank you to arXiv for use of its open access interoperability. This service was not reviewed or approved by, nor does it necessarily express or reflect the policies or opinions of, arXiv.

Record

Archive ID
arxiv:2012.05956
Published
Dec 10, 2020
DOI
10.1116/6.0000848
arXiv
2012.05956
Categories
physics.acc-ph
Provenance
arxiv