LCLS-II-HE verification cryomodule high gradient performance and quench behavior

S. Posen, A. Cravatta, M. Checchin, S. Aderhold, C. Adolphsen, T. Arkan, D. Bafia, A. Benwell, D. Bice, B. Chase, C. Contreras-Martinez, L. Dootlittle, J. Fuerst, D. Gonnella, A. Grassellino, C. Grimm, B. Hansen, E. Harms, B. Hartsell, G. Hays, J. Holzbauer, S. Hoobler, J. Kaluzny, T. Khabiboulline, M. Kucera, and 21 more

Preprint: not peer reviewed. Results may change in later versions.

Abstract

An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were processed with a novel nitrogen doping treatment to improve gradient performance. The cryomodule was tested with a modified protocol to process sporadic quenches, which were observed in LCLS-II production cryomodules and are attributed to multipacting. Dedicated vertical test experiments support the attribution to multipacting. The verification cryomodule achieved an acceleration voltage of 200 MV in continuous wave mode, corresponding to an average accelerating gradient of 24.1 MV/m, significantly exceeding the specification of 173 MV. The average Q0 (3.0x10^10) also exceeded its specification (2.7x10^10). After processing, no field emission was observed up to the maximum gradient of each cavity. This paper reviews the cryomodule performance and discusses operational issues and mitigations implemented during the several month program.

Abstract: arXiv descriptive metadata (CC0). Thank you to arXiv for use of its open access interoperability. This service was not reviewed or approved by, nor does it necessarily express or reflect the policies or opinions of, arXiv.

Record

Archive ID
arxiv:2110.14580
Published
Oct 27, 2021
arXiv
2110.14580
Categories
physics.acc-ph
Provenance
arxiv