SpineNetV2: Automated Detection, Labelling and Radiological Grading Of Clinical MR Scans

Rhydian Windsor, Amir Jamaludin, Timor Kadir, Andrew Zisserman

Preprint: not peer reviewed. Results may change in later versions.

Abstract

This technical report presents SpineNetV2, an automated tool which: (i) detects and labels vertebral bodies in clinical spinal magnetic resonance (MR) scans across a range of commonly used sequences; and (ii) performs radiological grading of lumbar intervertebral discs in T2-weighted scans for a range of common degenerative changes. SpineNetV2 improves over the original SpineNet software in two ways: (1) The vertebral body detection stage is significantly faster, more accurate and works across a range of fields-of-view (as opposed to just lumbar scans). (2) Radiological grading adopts a more powerful architecture, adding several new grading schemes without loss in performance. A demo of the software is available at the project website: http://zeus.robots.ox.ac.uk/spinenet2/.

Abstract: arXiv descriptive metadata (CC0). Thank you to arXiv for use of its open access interoperability. This service was not reviewed or approved by, nor does it necessarily express or reflect the policies or opinions of, arXiv.

Record

Archive ID
arxiv:2205.01683
Published
May 3, 2022
arXiv
2205.01683
Categories
eess.IV, cs.CV
Provenance
arxiv