Near-exact Upper Confidence Limits for Axion Haloscopes

Andrea Gallo Rosso, Jan Conrad

Preprint: not peer reviewed. Results may change in later versions.

Abstract

The data acquisition of axion haloscopes commonly implements sequential adaptive frequency scans. We present a method to calculate likelihood-based upper confidence limits on axion-photon coupling under this circumstance. We compare the likelihood-based method conceptually and quantitatively with tailor-made methods, i.e. the one proposed by Brubaker et al. (Geometric) and its upgrade the Bayesian Power-Measured (BPM) framework proposed by Palken et al. We find that the likelihood method yields average upper limits that are significantly more constraining than those obtained from these methods. For example, expected constraints improve by a factor of 1.4 as compared with the current state of the art when applied to projections for the ALPHA Plasma-haloscope. We further clarify the statistical basis for the Geometric and BPM methods. In particular, we point out the correspondence of BPM to e-values, proposed as an alternative to conventional p-values in statistics.

Abstract: arXiv descriptive metadata (CC0). Thank you to arXiv for use of its open access interoperability. This service was not reviewed or approved by, nor does it necessarily express or reflect the policies or opinions of, arXiv.

Record