Safety of a large language model-based clinical decision support system in African primary healthcare

Agweyu A, Mwaniki P, Musau W, Korom R, Isaaka L, Wanyama C, Kiptinness S, Adan N, Emmanuel-Fabula M, Mateen BA

View at source ↗PDF ↗Article7 citations

Abstract

Here we conducted a retrospective evaluation of an electronic medical record-embedded large language model clinical decision support system deployed across 16 primary care clinics in Kenya, between July and September 2024. A panel of trained physicians reviewed 1,469 records. Hallucinations were uncommon, occurring in 50 encounters (3.4%, 95% confidence interval (CI) 2.5-4.5), and most often involved misexpanded acronyms or drug names. Clinical management guidance aligned with local guidelines in almost all cases (1,455; 99%, 95% CI 98.4-99.5). Despite this, clinicians did not modify documentation in 917 encounters (62%, 95% CI 59.9-64.9). Safety assessments identified actively harmful recommendations from the large language model in 115 encounters (7.8%, 95% CI 6.5-9.3), with 67 such recommendations appearing in the final documentation. Conversely, risk present in the clinician's initial notes was fully mitigated in 118 encounters (8.0%, 95% CI 6.7-9.5 overall; 12.1%, 95% CI 9.5-15.2 of amended cases). Overall, the tool showed strong potential to support quality improvement, but the asymmetric adoption of harmful versus beneficial outputs underscores the need for usability optimization, local guardrails and prospective trials to confirm patient-level benefit.

Abstract of "Safety of a large language model-based clinical decision support system in African primary healthcare" by Agweyu A, Mwaniki P, Musau W et al., https://doi.org/10.1038/s44360-026-00082-5, used under its Creative Commons Attribution license (CC-BY); markup removed, otherwise unmodified.

Record

Archive ID
doi:10.1038/s44360-026-00082-5
Published
Mar 10, 2026
Venue
Nature health
DOI
10.1038/s44360-026-00082-5
PubMed
42272940
PMC
PMC13246507
License
CC-BY
Provenance
europepmc

Topics