Ultra high-density, 4096-channel intraoperative neurophysiological brain mapping for functional localization of the human central sulcus

Skular AF, Tostaeva G, Ho E, Dister J, Cummins DD, Barth K, Nunez L, Poole A, Mermel CH, Rapoport B, Bederson JB, Saez I

Abstract

Objective. Intraoperative localization of the central sulcus (CS) using somatosensory evoked-potential (SSEP) phase reversal (PR) is routinely performed with sparse subdural strip electrodes. We evaluated whether a multi-array, 4096-channel surface micro-electrocorticography ( μ ECoG) configuration could provide dense two-dimensional sampling of stimulus-dependent sensorimotor responses within a standard neurosurgical workflow. Approach. Four Precision Neuroscience Layer 7 μ ECoG arrays (1024 platinum electrodes per array on a flexible polyimide substrate, 400 μ m electrode pitch, ∼1.5 cm 2 active area per array) were deployed during resection of a right parafalcine meningioma in a 56-year-old male. Two arrays were placed horizontally on the exposed precentral gyrus; two were inserted under the intact dura overlying the postcentral gyrus, using a custom flexible stylet. Somatosensory evoked potentials (SSEPs) were recorded across five contralateral stimulation conditions (median nerve, ulnar nerve, index finger, middle finger, ring finger). Per-electrode SSEP responses were classified without anatomical labels, and spatial organization was quantified across stimulation conditions. Stimulus-locked high-gamma activity, digit-response maps, and signal quality across micro- and macroelectrodes were also evaluated. Main results. Aggregate channel yield was 91.3% (3739/4096) at a 2 MΩ impedance criterion (per-array range 86.7%-97.0%). Per-electrode amplitude maps resolved continuous phase-reversal contours with stimulus-specific spatial structure; reversal latencies were 19, 21, 25, 26, and 25 ms for median, ulnar, index, middle, and ring stimulation respectively. PR occurred within a single array in eight of ten sensory-array recordings, with the phase-reversal pattern varying across stimulation conditions. Digit responses showed measurable spatial differentiation within substantially overlapping response fields. Automated classification of the phase-reversal responses recovered the expected motor and sensory organization, consistent with the standard-of-care intraoperative localization performed in the same case. Significance. The deployment shows that a four-array Layer 7 μ ECoG configuration can be used within a standard neurosurgical exposure and provides dense two-dimensional sampling of stimulus-dependent phase-reversal patterns across the peri-Rolandic recording field. The measured responses were correlated across approximately 3-4 mm of cortex, an order of magnitude coarser than the 400 μ m electrode pitch, so the contribution demonstrated here is dense spatial sampling rather than submillimeter physiological resolution. Dense sampling rendered the polarity transition as a continuous two-dimensional boundary across the recording field rather than as a reversal between two adjacent contacts. The platform supports future evaluation of high-density surface μ ECoG for intraoperative mapping and chronic brain-computer interface applications.

Abstract of "Ultra high-density, 4096-channel intraoperative neurophysiological brain mapping for functional localization of the human central sulcus" by Skular AF, Tostaeva G, Ho E et al., https://doi.org/10.1088/1741-2552/aea70f, used under its Creative Commons Attribution license (CC-BY); markup removed, otherwise unmodified.

Record

Archive ID
doi:10.1088/1741-2552/aea70f
Published
Oct 21, 2026
Venue
Journal of neural engineering
DOI
10.1088/1741-2552/aea70f
PubMed
42735699
License
CC-BY
Provenance
europepmc

Topics